Skip to main content

SonarQube SonarScanner reference for STO

You can run scans and ingest results from SonarQube SonarScanner to analyze your code repos and ensure that they are secure, reliable, readable, and modular, among other key attributes.

Important notes for running SonarQube scans in STO

  • STO supports repository scanning only for SonarScanner.
  • STO supports all languages supported by SonarScanner.
  • Before you scan your repo, make sure that you perform any prerequisites for the language used in your repo. For details about specific language requirements, go to the SonarQube language reference.
  • By default, STO allocates 500Mi memory for the Sonarqube scan container. This should be enough for Ingestion scans. For Orchestration and Extraction scans, Harness recommends that you allocate at least 2GB for the container. You can customize resource limits in the Set Container Resources section of the SonarQube scan step.
  • You need to run the scan step with root access if you need to add trusted certificates to your scan images at runtime.
  • You can set up your STO scan images and pipelines to run scans as non-root and establish trust for your own proxies using self-signed certificates. For more information, go to Configure STO to Download Images from a Private Registry.

For more information

The following topics contain useful information for setting up scanner integrations in STO:

SonarQube step settings for STO scans

The recommended workflow is to add a SonarQube step to a Security Tests or CI Build stage and then configure it as described below.

A Docker-in-Docker background step is not required for this workflow.

Scan

Scan Mode

  • Orchestration Configure the step to run a scan and then ingest, normalize, and deduplicate the results.

Scan Configuration

The predefined configuration to use for the scan. All scan steps have at least one configuration.

Target

Type

  • Repository Scan a codebase repo.

    In most cases, you specify the codebase using a code repo connector that connects to the Git account or repository where your code is stored. For information, go to Configure codebase.

Name

The identifier for the target, such as codebaseAlpha or jsmith/myalphaservice. Descriptive target names make it much easier to navigate your scan data in the STO UI.

It is good practice to specify a baseline for every target.

Variant

The identifier for the specific variant to scan. This is usually the branch name, image tag, or product version. Harness maintains a historical trend for each variant.

Workspace

The workspace path on the pod running the scan step. The workspace path is /harness by default.

You can override this if you want to scan only a subset of the workspace. For example, suppose the pipeline publishes artifacts to a subfolder /tmp/artifacts and you want to scan these artifacts only. In this case, you can specify the workspace path as /harness/tmp/artifacts.

Ingestion File

The path to your scan results when running an Ingestion scan, for example /shared/scan_results/myscan.latest.sarif.

  • The data file must be in a supported format for the scanner.

  • The data file must be accessible to the scan step. It's good practice to save your results files to a shared path in your stage. In the visual editor, go to the stage where you're running the scan. Then go to Overview > Shared Paths. You can also add the path to the YAML stage definition like this:

        - stage:
    spec:
    sharedPaths:
    - /shared/scan_results

Authentication

Domain

The URL of the SonarQube server. Required for Orchestration and Extraction scans. This value corresponds to the sonar.host.url setting in SonarQube.

The fully-qualified URL to the scanner.

Enforce SSL

The step and the scanner communicate over SSL by default. Set this to false to disable SSL (not safe).

Access Token

The access token to log in to the scanner. In most cases this is a password or an API key.

You should create a Harness text secret with your encrypted token and reference the secret using the format <+secrets.getValue("project.my-access-token")>. For more information, go to Add and Reference Text Secrets.

note

Harness recommends that you use a SonarQube user token that includes permissions to run scans and to create projects.

If you use a project token, you must have access to the SonarQube project that you want to scan.

For more information, go to Generating and using tokens in the SonarQube documentation.

Scan Tool

Exclude

If you want to exclude some files from a scan, you can use this setting to configure the sonar.exclusions in your SonarQube project. For more information, go to Narrowing the Focus in the SonarQube docs.

Java Libraries

A comma-separated list of paths to files with third-party libraries used by your tests. For SonarQube scans, this corresponds to the sonar.java.libraries parameter.

Java Binaries

A comma-separated list of paths to the folders with the bytecode files you want to scan. For SonarQube scans, this corresponds to the sonar.java.binaries parameter.

Log Level, CLI flags, and Fail on Severity

Log Level

The minimum severity of the messages you want to include in your scan logs. You can specify one of the following:

  • DEBUG
  • INFO
  • WARNING
  • ERROR

Additional CLI flags

You can add CLI flags to run the sonar-scanner binary with specific command-line arguments. For example, suppose the scan is experiencing timeouts due to long response times from a web service. The following flag increases the timeout window: -sonar.ws.timeout 300

Fail on Severity

Every Security step has a Fail on Severity setting. If the scan finds any vulnerability with the specified severity level or higher, the pipeline fails automatically. You can specify one of the following:

  • CRITICAL
  • HIGH
  • MEDIUM
  • LOW
  • INFO
  • NONE — Do not fail on severity

The YAML definition looks like this: fail_on_severity : critical # | high | medium | low | info | none

Additional Configuration

In the Additional Configuration settings, you can use the following options:

Advanced settings

In the Advanced settings, you can use the following options: